Error description

  • RPT 8.5.1 reports AMF transform error for POST content that
    worked with RPT 8.3.0.3
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    RPT 8.5.1 reports AMF transform error for POST content that
    did not cause an error with RPT 8.3.0.3.  However, the RPT
    8.3.0.3 transformation was not correct; RPT cannot correctly
    transform this AMF content without access to user classes.
    

Problem conclusion

  • In 8.3.0.3, the transformation did not report a problem but
    did not actually transform correctly since user classes were
    required.  This situation is now detected in 8.5.1, hence
    the customer sees an error which did not appear before.
    When such things happen, the only thing we can suggest is to
    use another AMF 3 transformer (currently the only other one
    existing is the GraniteDS one) which requires the user to
    place the jar containing the definition of the exchanged
    classes in the classpath of the test project.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI07419

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-12-04

  • Closed date

    2014-01-24

  • Last modified date

    2014-01-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

  • R851 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021