IBM Support

PH10756: DOORS: WRITE TO STREAM DXL CAUSES EXCEPTION ACCESS VIOLATION

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • Running the following DXL which is a sample from the DXL
    reference manual, will cause an exception access violation
    error:
    Stream alpha = write "c:\\temp\\streamout.txt"
    alpha << 'a' << 'b' << 'c'
    
    -R-E- DXL: An unexpected error has occurred: ntdll.dll caused an
    EXCEPTION_ACCESS_VIOLATION in module ntdll.dll at
    00000000C369A6FB
    -R-F- DXL: internal error, please submit a bug report -I- DXL:
    execution halted
    
    The output file gets created and contains an 'a' character.
    Using an older 32 bit DOORS client such as 9.6.0.1, does not
    cause the same crash when running the DXL.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All DOORS users.                                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Write to DXL stream causes exception access violation.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.7 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH10756

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-04-08

  • Closed date

    2019-07-05

  • Last modified date

    2019-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PH10756