IBM Support

PH05125: RDZ V9.5.1.4 - BASE INFORMATION IS MISSING WHEN GENERATING THE INCLUDES FOR SDF2

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

Local fix

  • (1) Assemble the map using JCL, or
    (2) Edit the resulting file and add the appropriate clause.
    

Problem summary

  • The COBOL copybook or PLI include file resulting from using the
    Generate > Symbolic Map menu action in IDz (and RDz) does not
    contain the appropriate REDEFINES clause for COBOL or BASED
    clause for PLI when the BASE option is used in the BMS mapset
    definition.
    

Problem conclusion

  • The appropriate REDEFINES clause for COBOL or BASED clause for
    PLI is generated when the BASE option is used in the BMS mapset
    definition.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH05125

  • Reported component name

    DEV FOR Z SYS

  • Reported component ID

    5724T0700

  • Reported release

    951

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-11

  • Closed date

    2019-04-30

  • Last modified date

    2019-04-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DEV FOR Z SYS

  • Fixed component ID

    5724T0700