Error description

  • If you attempt to follow a link from the history entry for link
    creation, and that history entry exists in a baseline, and there
    is no history in the current version for the object, a DXL error
    will be given.
    
    To recreate:
    
     - create a module containing some objects
     - create a link between 2 of the objects
     - save the module and create a baseline
     - right-click on the source object and select Properties
     - in the objects properties dialog select the history tab
     - click <Load Previous> to load the baseline history
     - select the history entry for the link creation then click
    <Goto Target Object>
    
    The error given in the v9.6.1.11 client is:
    
    "
    -R-E- DXL: <standard/history/historyTab.inc:2264> unassigned
    variable (h)
    Backtrace:
    	<standard/history/historyTab.inc:2264>
    	<standard/object/properties.dxl:628>
    	<standard/history/historyTab.inc:2264>
    	<standard/object/properties.dxl:628>
    "
    
    Workaround:
    
    Manual link navigation will be possible.
    Or, as soon as a history entry exists in the current version for
    the object the problem no longer happens.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All DOORS users.                                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Following a link from baseline history results in a DXL      *
    * error if there is no history in the current version for that *
    * object.                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.7 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH04946

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-06

  • Closed date

    2019-07-10

  • Last modified date

    2019-07-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PH04946

Modified date: 10 July 2019