Error description

  • When performing multiple Subscribe actions using the same
    transport in a test, the test takes a long time to complete.
    
    STEPS TO REPRODUCE:
    
    1. Create a test with an iterator.
    2. Place a File Subscribe inside the loop.
    3. Run the test.
    
    EXPECTED RESULTS:
    
    Rapid test execution.
    
    ACTUAL RESULTS:
    
    Each iteration takes several seconds.
    
    
    WORKAROUND:
    
    Set the Poll interval on the Subscribe action to the minimum 1
    second.
    The default is 10 seconds.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of Rational Integration Tester using the File          *
    * transport to process multiple files in a loop.               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When subscribing to files in a directory within a loop in a  *
    * test, and each subscribe is for a different file, the loop   *
    * might run slowly with one file processed for each poll of    *
    * the file system.                                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in 9.2.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH00540

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-07-16

  • Closed date

    2018-10-03

  • Last modified date

    2018-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels



Document information

More support for: Rational Test Workbench

Software version: 920

Reference #: PH00540

Modified date: 03 October 2018