IBM Support

OA58302: TRIGGER SYSTEM RECOVERY BOOST DURING SYSTEM SHUTDOWN FROM INGREQ OR VIA GDPS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • SHUTDOWN BOOST
    E8561/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SA z/OS V4R1 customers.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: SA should be enhanced to support the    *
    *                      automatic activation of System          *
    *                      Recovery Boost at system shutdown.      *
    *                                                              *
    *                      E8561/K                                 *
    ****************************************************************
    IBM Z System Recovery Boost is a new feature that is available
    with the IBM z15 (z15). It can temporarily leverage additional
    processor capacity during IPL and shutdown times to reduce the
    overall downtime due to recovery or maintenance activities.
    This new function requires z/OS V2.3 and OA57849 or z/OS V2.4.
    At IPL time, a system can automatically participate in the boost
    unless the BOOST system parameter in IEASYSxx is set to NONE.
    At shutdown time, the operator has to explicitly activate the
    boost by starting the new started procedure IEASDBS that is
    provided by z/OS.
    
    With OA58302, support is added to SA z/OS to automatically
    activate System Recovery Boost upon shutdown of a system.
    SA z/OS checks whether the operational prerequisites are met
    and if so starts the started procedure IEASDBS. Specifically,
    SA z/OS checks whether it runs on z/OS V2.3 or higher, whether
    boost is enabled in IEASYSxx and that the system is not already
    operating in boost mode. IEASDBS is started only when all
    conditions are met.
    SA z/OS does not check whether it runs on a z15.
    
    If System Recovery Boost should not be activated automatically
    upon system shutdown, even if enabled by the operating system,
    the administrator can pass the new INGREQ parameter BOOST=NO
    with the INGREQ ALL request. To permanently disable System
    Recovery Boost during shutdown of a system, the administrator
    can set the global variable INGREQ_BOOST to NO.
    
    When a system is shut down via GDPS, SA z/OS also automatically
    activates System Recovery Boost when the operational
    prerequisites are met. To avoid automatic activation of System
    Recovery Boost, the administrator can set the advanced
    automation option AOF_AAO_SHUTDOWN_BOOST to NO.
    
    IEASDBS activates System Recovery Boost only once. If it has
    been started manually before an operator requests a shutdown via
    SA z/OS, SA z/OS will detect it and not start the procedure
    again. If the procedure is started manually after an operator
    requests shutdown via z/OS and z/OS has already started it
    automatically, messages on the system console indicate that an
    error occurred but no further action is required.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    OA58302

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    410

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-09-09

  • Closed date

    2019-09-25

  • Last modified date

    2019-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ00933 UJ00934

Modules/Macros

  • AOFAUTB  AOFEXC01 AOFEXC15 HSAPRSYS ING#REQ  INGCMD   INGH$RU
    INGKYRU2 INGRTERM INGRVRU4 INGRVRU5 INGRYRU0
    

Publications Referenced
SC34272001SC34271501   

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R410 PSY UJ00933

       UP19/10/01 P F909

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information