IBM Support

IV84907: WHEN THE LOCATION FIELD IS READONLY THE VALUE CAN BE CHANGED USING THE DRILLDOWN OPTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the Location field is readonly the value can be changed
    using the drilldown option
    
    PROBLEM:
    
    When the location field in the SR is changed to read-only it
    can't be changed using the lookup but it CAN be changed using
    the drilldown option.
    
    PERFORMANCE ISSUE: NO.
    
    STEPS TO REPRODUCE:
    
    Go to Application Designer
    Bring up the SR app
    From the main tab open the textbox properties for Location field
    Set input mode to Readonly
    Save it
    Go to SR app
    Bring up a record with an existing Location
    Click the drill down option and choose any other location
    The Location is changed and you are able to save the record.
    
    
    CURRENT ERRONEOUS RESULT:
    
    The Location is changed and you are able to save the record.
    
    
    EXPECTED RESULT:
    
    The Location should not be changed using the drilldown option.
    
    
    ENVIRONMENT (SYSTEM INFO):
    
    TPAE 7.5.0.5
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * N/A                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * WHEN THE LOCATION FIELD IS READONLY THE VALUE CAN BE CHANGED *
    * USING THE DRILLDOWN OPTION                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Fixed in Tpae 7.5.0.11 fix pack.                             *
    ****************************************************************
    

Problem conclusion

  • Added readonly check in DrilldownTreeBean.java.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV84907

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-17

  • Closed date

    2016-10-13

  • Last modified date

    2016-10-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
13 October 2016