A fix is available
APAR status
Closed as program error.
Error description
Using the filter "Compare Date and Time" seems to return no data. We observe the timestamp displayed in the report, and try to create a filter with the exact same timestamp, but once applied no data is returned. Attached video "TimestampFilter.wmv" is a video demonstrating the behavior. The videos demonstrates the issues using IBM Tivoli Advanced Reporting for DFSMShsm, but it seems to happen for other products also. Material received from HTTP server and stored in ECuRep: Directory: /ecurep/pmr/9/1/91082,L6Q,000/2012-11-27 File: 91082.L6Q.000.90991.L6Q.000.TimestampFilter.wmv 1467598 bytes
Local fix
N/A
Problem summary
On the portal client, an empty or incorrect view may be displayed if a 'Compare Date and Time' function is used to filter the result set on a time stamp value. On the portal client, an empty or incorrect view may be displayed if a 'Compare Date and Time' function is used to filter the result set on a time stamp value. An 'equal' comparison will almost always result in an empty view while 'less than' or 'greater than' comparisons may include more or less data rows than expected. A 'not equal' comparison will almost always be true for all data rows.
Problem conclusion
The time stamp filter logic was changed to ignore the millisecond part of time stamp data values when comparing against the user-provided comparison value unless that value explicitly includes milliseconds. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0003
Temporary fix
Comments
APAR Information
APAR number
IV33958
Reported component name
TEP
Reported component ID
5724C04EP
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-21
Closed date
2014-03-25
Last modified date
2014-08-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEP
Fixed component ID
5724C04EP
Applicable component levels
R630 PSY
UP