  • Closed as program error.

Error description

  • CD Requester Select Statistics reports Invalid Parameter when
    the RecordCategory service parameter is set to one category
    value (eg. CAPR).
    

Local fix

  • STRRTC - B2BISFG-53200
    JW / JW
    Circumvention: <None /
    workaround>
    

Problem summary

  • Users Affected:
    
    B2B Integrator 5.2
    
    Problem Description:
    
    The Connect:Direct Select Statistics Service reports "LCCA052I
    Invalid Parameter" when specifying the RecordCategory parameter
    with the value 'CAPR'. The same error is reported when
    specifying the RecordId parameter with the value 'PRED'.
    
    
    
    Platforms affected:
    
    Unix/Linux
    
    Windows
    
    iSeries
    

Problem conclusion

  •  Resolution Summary:
    A code fix is provided.
    Handling for the RecordCategory and RecordId service parameters
    in the Select Statistics Service has been corrected. In addition
    to these Select Statistics Service parameters, ProcessName,
    ProcessNumber, ConditionCodeOperation, ConditionCodeValue,
    Snode, StartDate, StartTime, StopDate, StopTime, Submitter,
    SourceFile and DestinationFile are now supported.
    
    
    
    Delivered In:
    
    6000303
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT33635

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    603

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-21

  • Closed date

    2020-11-11

  • Last modified date

    2020-11-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"603"}]

Document Information

Modified date:
13 November 2020