APAR status
Closed as program error.
Error description
DEBUG mode on Security.log re-activated after Sterling B2B Integrator restart Although the de-activate the Security.log logger in SI Dashboard (system_overrides.properties is updated accordingly), the DEBUG mode on this logger is re-activated each time the system is restarted.
Local fix
STRRTC - TS003259327 JN / JN Circumvention: None / workaround
Problem summary
Users Affected: All Problem Description: DEBUG mode on Security.log re-activated after Sterling B2B Integrator restart. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Fix has been made such that whenever we change the log level or log file max size in Sterling B2B Integrator UI, it adds/updates entry in system_overrides file and also adds/updates the same in tuning_properties table. So even after SI restart, the changes in log serviceof UI will remains same. Delivered in: 6000303
Temporary fix
Comments
APAR Information
APAR number
IT33200
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
603
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-16
Closed date
2020-11-11
Last modified date
2020-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"603"}]
Document Information
Modified date:
13 November 2020