IT32753: FTP CLIENT-GET SERVICE WITH DELAYWAITINGONIO SET TO -1 DOES NOT WORK ON 5.2.6.3_12

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The delayWaitingOnIO=-1 set in the FTP Client Get Service is
    not being honored and the GET service enters the Waiting_On_IO
    state after 30s by default.
    

Local fix

  • STRRTC - L3REQ-801
    SBN / SBN
    Circumvention - NONE
    

Problem summary

  • Users Affected:
    
    All
    
    Problem Description:
    
    FTP Client GET service with delayWaitingOnIO set to -1 does not
    work on 5.2.6.3_12.
    
    
    
    Platforms Affected:
    
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix is provided.
    This is a regression caused by another fix which changed the
    behavior of
    
    1. Ftp Client Begin Session Service
    
    2. Ftp Client Get Service
    
    3. Ftp Client Put Service and
    
    4. Ftp Client Delete Service
    
    where the delayWaitingOnIO = -1 in the business process wasn't
    being
    honored and these services would still be forced to enter the
    WAITING_ON_IO state after 30s; which is the default
    responseTimeOut value.
    
    
    
    Made code changes to remove this regression and to exhibit the
    intended desgined behavior by these above 4 services when
    delayWaitingOnIO=-1.
    
    
    
    Delivered in:
    
    5020603_15
    6000005
    5020605_3
    6000006
    6000304
    6010002
    6000007
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT32753

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    526

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-04

  • Closed date

    2020-06-11

  • Last modified date

    2021-07-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6"}]

Document Information

Modified date:
30 July 2021