APAR status
Closed as new function.
Error description
IBM Sterling B2B Integrator by default adds the <mcd> folder to the RFH header data while this is an optional field per WMQ.
Local fix
STRRTC - L3REQ-1008 SBN / SBN Circumvention - NONE
Problem summary
Users Affected: All Problem Description: Suppress/Remove the default inclusion of the <mcd> folder structure in the header data by the MQHRF2 service. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. By default, B2BI adds the <mcd> folder contents in the MQHRF2 header data. To suppress this <mcd> folder, set the property setting, 'addDefaultMcdFolder = false' in the wsmq.properties file. A new property AddDefaultMcdFolder is added in wsmq.properties file, this is to suppress the additional tags in the header. By default, it is set to true. When it is set to true, we get additional tags as <mcd><Msd>none</Msd></mcd>. When it is set to false, we do not get those additional tags. Delivered in: 6000203
Temporary fix
Comments
APAR Information
APAR number
IT32524
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
602
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-04-10
Closed date
2020-11-26
Last modified date
2020-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"602"}]
Document Information
Modified date:
02 December 2020