IBM Support

IT30858: TTL VALUE IN FS MODULE IS HANDLED DIFFERENTLY FROM THE SETTING.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • The file created with TTL 86400 seconds is deleted in 20864
    seconds.
    

Local fix

Problem summary

  • When DataPower user uses the fs() method in GatewayScript for
    file system accessing and sets a TTL (time to live) value which
    is larger than 65535, the fs function won't work with the
    expected TTL value.
    

Problem conclusion

Temporary fix

  • Avoid using large value for TTL setting.
    

Comments

APAR Information

  • APAR number

    IT30858

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-11-06

  • Closed date

    2019-12-05

  • Last modified date

    2019-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels



Document information

More support for: IBM DataPower Gateways
General

Software version: 18X

Reference #: IT30858

Modified date: 05 December 2019