APAR status
Closed as program error.
Error description
IBM Sterling B2B Integrator taking down the hsm device by sending too many transactions.
Local fix
RTC# B2BISFG-477
Problem summary
Users Affected: All Problem Description: A problem in PKCS11 security provider for HSM device exists, so some cryptographic operations are done on the HSM device instead of locally. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Delivered in: 5020603_13 6000004 6000102 5020605_1 6000301 6000202 5020604_4 6010000
Temporary fix
Comments
APAR Information
APAR number
IT30848
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-05
Closed date
2019-12-18
Last modified date
2020-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6"}]
Document Information
Modified date:
21 September 2020