IT29775: THE SFTP CLIENT END SESSION SERVICE HANGS IN "WAITING ON IO" STATUS IN IBM STERLING B2B INTEGRATOR V6.0.1

Direct link to fix

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The SFTP Client End Session service in IBM Sterling B2B
    Integrator v6.0.1 hangs in
    "Waiting On IO" status while connecting to the SFTP
    Servers.
    

Local fix

  • RTC - 585752
    KK / KK
    Circumvention: None
    

Problem summary

  • Users Affected:
    All
    
    Problem Description:
    The SFTP Client End Session service hangs in "waiting on IO"
    status in IBM Sterling B2B Integrator v6.0.1.
    
    Platform Affected:
    asset
    

Problem conclusion

  • Resolution Summary:
    
    A code fix is provided.
    
    Delivered In:
    5020604_2
    6000101
    6000201
    6000300
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT29775

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-07-26

  • Closed date

    2019-08-01

  • Last modified date

    2020-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
13 September 2023