Error description

  • If a DataPower service, such as the Multi-Protocol Gateway, has
    a transaction-timeout configured with a non-zero value, and
    persistent connections are enabled on the Front Side Handler,
    the service might incorrectly cancel a transaction that is sent
    over a reused connection, if the connection has been idle for
    longer than the configured transaction-timeout.
    

Local fix

Problem summary

  • Affected is the use of persistent connections.
    A transaction might be incorrectly canceled in case a non-zero
    connection timeout is configured.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT29236

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-29

  • Closed date

    2019-07-18

  • Last modified date

    2019-07-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels



Document information

More support for: IBM DataPower Gateways
General

Software version: 760

Reference #: IT29236

Modified date: 24 July 2019