IBM Support

IT29074: DATAPOWER MIGHT RELOAD UNEXPECTEDLY IF INFLIGHT TRAFFIC MEETS AN IN-PROGRESS API GATEWAY CONFIG CHANGE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The user observed an unexpected reload of DataPower Gateway
    while taking active through an API Gateway service which at
    same time got applied a configuration change.
    The logs showed "Local configuration modified by script"
    followed shortly after by "Assembly rule
    'my_xyz_thing_1.0.0_main' is not up for execution" for that
    specific configuration.
    

Local fix

  • Ensure API config changes get only pushed to the gateway while
    it is not taking traffic.
    

Problem summary

  • DataPower might unexpectedly reload while updating an API
    service configuration.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT29074

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-09

  • Closed date

    2019-05-24

  • Last modified date

    2019-05-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R18X PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]

Document Information

Modified date:
27 September 2021