Error description

  • When attempting to use the copy command in application domain,
    the command will fail with an error message stating 'Access
    Denied'.  For example:
    idg(config)# show usergroup exampleGroup
    usergroup: exampleGroup [up]
    -------------------
     admin-state enabled
     summary "Example User Group"
     access-policy */*/*?Access=rwadx
    idg(config)# top;co;copy -f http://google.com:80
    local:test/get.txt
    Global configuration mode
    File copy success (46764 bytes copied)
    idg(config)# switch ApplicationDomain
    idg[ApplicationDomain](config)# top;co;copy -f
    http://google.com:80 local:test/get.txt
    Global configuration mode
    % Access Denied - use 'cancel' to exit any submode.
    

Local fix

  • There are two possible workarounds to this issue:
      1. Turn off "apply to CLI" parameter in RBM settings (default
    domain)
      2. Do not use the -f flag within copy command.  For example:
    idg[ApplicationDomain](config)# top;co;copy
    http://google.com:80 local:test/get.txt
    Global configuration mode
    Copy: overwrite 'local:test/get.txt'? Yes/No [y/n]: y
    File copy success (46781 bytes copied)
    

Problem summary

  • Using the copy command when enable RBM is on for CLI, the copy
    command may fail with "Access Denied".
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT24601

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    752

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-03

  • Closed date

    2018-05-17

  • Last modified date

    2018-05-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 0
    

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R770 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"752","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022