IT23508: DATAPOWER XQUERY SCRIPT WITH OUTPUT METHOD JSON TRIGGERS DATAPOWER RESTART IF ITS OUTPUT IS EMPTY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the output method of XQuery script is set to JSON but its
    output is empty, DataPower restarts.
    

Local fix

  • Ensure that the output is non-empty, for instance by wrapping
    the response in "[..]".
    

Problem summary

  • Affected is use of DataPower XQuery.
    
    If the output method of XQuery script is set to JSON but its
    output is empty, DataPower restarts.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT23508

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-14

  • Closed date

    2018-05-18

  • Last modified date

    2018-05-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R750 PSY

       UP

  • R751 PSY

       UP

  • R752 PSY

       UP

  • R760 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022