IBM Support

IT22852: THERE MIGHT BE SOME STARTUP-CONFIG ERROR IN VIRTUAL EDITION

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • There might be some startup-config error in virtual edition and
    generate the below errors during startup.
    Sun Oct 15 2017 23:57:49 [0x81000001][cli][error] : *** Unknown
    command or macro
    Sun Oct 15 2017 23:57:49 [0x81000223][cli][error] :
    (startup-config:714):   admin-state disabled
    Sun Oct 15 2017 23:57:49 [0x81000489][cli][error] : Encountered
    an unexpected exit directive while processing the startup
    configuration script.
    In startup-config file, it's the dummy node below causing the
    error.
    %if% available ""
      admin-state disabled
    exit
    %endif%
    If the issue do not affect complete of startup running, the
    error can be ignored.
    

Local fix

Problem summary

  • Errors regarding an unnamed object might be seen on device
    startup.
    

Problem conclusion

  • Creation of the unnamed object has been removed preventing the
    lines:
    %if% available ""
      admin-state disabled
    exit
    %endif%
    From occuring in the startup script.
    Fix is available in 7.2.0.18, 7.5.0.12, 7.5.1.11, 7.5.2.11
    For a list of the latest fix packs available, please see:
    http://www-01.ibm.com/support/docview.wss?uid=swg21237631
    

Temporary fix

  • N/A
    

Comments

APAR Information

  • APAR number

    IT22852

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    752

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-20

  • Closed date

    2017-12-05

  • Last modified date

    2019-01-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 0
    

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels



Document information

More support for: IBM DataPower Gateways
General

Software version: 752

Reference #: IT22852

Modified date: 08 January 2019