Fixes are available
APAR status
Closed as program error.
Error description
When SLM Multicast is configured, and the SLM type is switched to SLM Unicast via the WebGUI, the SLM Unicast might appear [up] but will not sync properly.
Local fix
Remove the ip-multicast object from the peer-group.
Problem summary
When switching from SLM Unicast to SLM Multicast or vice versa, unexpected Threshold limits might be allowed.
Problem conclusion
Fix is available in 7.1.0.21, 7.2.0.18, 7.5.0.12, 7.5.1.11, 7.5.2.11 and 7.6.0.4 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Save config and restart the domain after switching peer group types.
Comments
APAR Information
APAR number
IT20388
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
752
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-27
Closed date
2017-10-10
Last modified date
2017-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R760 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"752","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]