IT19580: SNMP TRAPS MIGHT NOT BE SENT

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When DataPower's SNMP settings monitor for a trap-code, the
    SNMP trap might not be sent even though a log message was
    generated matching the trap-code.
    

Local fix

Problem summary

  • Every other time snmp settings were modified traps would no
    longer be sent until the next modification.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT19580

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem