IBM Support

IT19084: XFORMBIN ACTION WITH OUTPUT CONTEXT PIPE ERRORS ON NON-XML C0 ASCII CONTROL CHARACTERS IN CASE PROBE IS ENABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If xformbin action output context is PIPE and contains Non-XML
    C0 control characters, then error gets logged. See below
    example for output
    ----------------------------------------------------------------
    ------------------
    $ curl --data-binary @<(echo -e '\x23\x0A\x23')
    http://dp1-l3.boeblingen.de.ibm.com:8099/test ; echo
    #
    #
    
    $ curl --data-binary @<(echo -e '\x23\x11\x23')
    http://dp1-l3.boeblingen.de.ibm.com:8099/test ; echo
    xmlns:env="http://schemas.xmlsoap.org/soap/envelope/"><env:Body>
    l Error (from
    client)</faultstring></env:Fault></env:Body></env:Envelope>
    $
    

Local fix

Problem summary

  • Affected is use of Probe.
    
    If xformbin action output context is PIPE and contains Non-XML
    C0 control characters, then error gets logged.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT19084

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-02

  • Closed date

    2017-08-23

  • Last modified date

    2017-10-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R750 PSY

       UP

  • R751 PSY

       UP

  • R752 PSY

       UP

  • R760 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022