IT18561: CONVERT STGPOOL MIGHT FAIL WITH ANR1893E WHEN THE RESOURCE TIMEOUT IS HIT

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The IBM Spectrum Protect CONVERT STGPOOL process might end with
    a failure message without providing details on the root cause:
    12/01/2016 13:09:34      ANR0984I Process 315 for CONVERT
    STGPOOL started in the BACKGROUND at 13:09:34. (SESSION: 30460,
    PROCESS: 315)
    ..
    12/01/2016 18:59:58      ANR0985I Process 315 for CONVERT
    STGPOOL running in the BACKGROUND completed with completion
    state FAILURE at 18:59:58. (SESSION: 30460, PROCESS: 315)
    12/01/2016 18:59:58      ANR1893E Process 315 for CONVERT
    STGPOOL completed with a completion state of FAILURE. (SESSION:
    30460, PROCESS: 315)
    
    A review of the actlog for the convert process messages does not
    give any further details that would explain what went wrong.
    Under the APAR condition, the following will be reported in the
    dsmffdc.log file for the CONVERT process:
    [12-01-2016 14:25:16.402][ FFDC_GENERAL_SERVER_ERROR ]:
    (sdbuf.c:804) Resource timeout while waiting for empty buffer.
    txnP 0x7f345c00df28
    
    A review of the actlog around the 14:25 timeframe does not give
    any error messages related to the convert process 315.
    
    The symptom was seen when processing very large objects and the
    server failed to allocate space for the object to process within
    the RESOURCETIMEOUT limit.
    Server messaging should be changed to allow identifying the root
    cause of the symptom.
    
      Tivoli Storage Manager Versions Affected: 7.1.6 and newer
      Customer/L2 Diagnostics (If Applicable) review the dsmffdc.log
    file for resource timeout messages
      Initial Impact: Low
      Additional Keywords: TSM container
    

Local fix

  • increase the timeout if the resource timeout message is in the
    dsmffdc.log file:
    - prior to 7.1.7, the timeout was governed by the
    RESOURCETIMEOUT, so increase the RESOURCETIMEOUT.
    - starting with 7.1.7 and later, it is now governed by
    CONTAINERRESOURCETIMEOUT which has a default of 180 mins
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IBM Tivoli Storage Manager and Spectrum Protect server   *
    * users.                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available. This problem is currently *
    * projected to be                                              *
    * fixed in levels 7.1.7.200, 7.1.8, and 8.1.1. Note that this  *
    * is subject to                                                *
    * change at the discretion of IBM.                             *
    ****************************************************************
    

Problem conclusion

  • This problem was fixed.
    Affected platforms for reported release:  AIX, Solaris, Linux,
    and
    Windows.
    Platforms fixed:   AIX, Solaris, Linux, and Windows.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT18561

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    71L

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-12-23

  • Closed date

    2017-02-28

  • Last modified date

    2017-02-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R71A PSY

       UP

  • R71L PSY

       UP

  • R71S PSY

       UP

  • R71W PSY

       UP



Document information

More support for: Tivoli Storage Manager

Software version: 7.1.3

Reference #: IT18561