IBM Support

IT17930: DATAPOWER MIGHT RESTART WHEN DISABLING A LOAD BALANCER GROUP WITH HEALTH CHECK IN PROGRESS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When disabling a Load Balancer Group (LBG) with Health Check
    Type
    of Standard ("type Standard" from the CLI) and also Independent
    Health Checks set to off ("no independent-checks" from the
    CLI), the device might restart if there is currently
    a health check in progress.
    

Local fix

  • Setting the Independent Health Checks to on if it is acceptable.
    

Problem summary

  • After the fix, DataPower will no longer unexpectedly restart
    when disabling a LBG with a Health Check Type of Standard that
    does not have Independent Health Checks enabled.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT17930

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-14

  • Closed date

    2017-01-05

  • Last modified date

    2017-01-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 0-0
    

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R752 PSY

       UP