Error description
When configuring an NFS Static Mount to enable Local-filesystem-access, DataPower allows the user to access the NFS directory via the nfs-MountName directory. From the CLI you can copy files to and from the NFS static mount in the following manner: # copy local:///somefile.txt nfs-MountName:///somefile.txt When the NFS mount is not up, the nfs-MountName directory is still accessible, thus a user can still copy files to this location; however, these files are not successfully transferred to the remote NFS server. In this case, the copy command will succeed and provide the following success message: File copy success (X bytes copied) However, checking the NFS remote server will yield that no file has been copied.
Local fix
Problem summary
Affected is the use of local file system access with an NFS mount. Copying to the mount directory is still allowed even if the NFS mount attempt was not successful. This causes a message indicating success to be issued even though the file did not actually make it to the NFS server.
Problem conclusion
Fix is available in 7.0.0.16, 7.1.0.13, 7.2.0.10, 7.5.0.4, 7.5.1.3 and 7.5.2.1 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT17195
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-23
Closed date
2016-11-07
Last modified date
2016-11-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0-0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R752 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.0"}]