A fix is available
APAR status
Closed as program error.
Error description
Datapower logs shows: "One or more inputs was invalid" WTX error after upgrade to 7.2 or higher firmware.
Local fix
Use GatewayScript action to strip off the XML declaration before the WTX map.
Problem summary
Affected is use of WTX transformation to process XML input data. If the user builds the WTX DPA map file and sets the "Type" of input card to the non-root item in the XML Scheme, then the WTX transformation may fail for input data with XML prolog.
Problem conclusion
Fix is available in 7.2.0.8, 7.5.0.2 and 7.5.1.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
1. Remove XML header (<?xml version="1.0" encoding="UTF-8"?>) from the input XML data. Or 2. Change in the native schema input card's "Type" to the "XSD" in root or change in Xerces type tree input card's "Type" to the "Doc XSD" in root. This only needs to done for the main native schema input card.
Comments
APAR Information
APAR number
IT16959
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-08
Closed date
2016-09-14
Last modified date
2016-09-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R720 PSY
UP
R750 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.2"}]
Document Information
Modified date:
26 September 2021