IBM Support

IT16948: TRANSFORM BINARY ACTION WITH NULL INPUT CONTEXT MAKES NULL INPUT CONTEXT XML-PARSING IN FOLLOWING ACTION ERROR ON PARSE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • If you use a binary transform action using the input context
    NULL, succeeded by an action parsing XML also using input
    context NULL, the transaction will fail.
    
    The following will be logged:
    [xmlparse] [error] 0x80e003aa mpgw (myMPG): Incomplete markup
    or missing document element at offset 0 of http://inputURI/
    [mpgw] [error] 0x00030001 mpgw (myMPG): Parse error
    

Local fix

  • Change order of actions.
    

Problem summary

  • Affected is the use of any action that parses XML with input
    context NULL.
    
    If a transform binary action with input context NULL precedes
    that action, parsing the NULL context as XML results incorrectly
    in a parse error then.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT16948

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-09-07

  • Closed date

    2017-02-01

  • Last modified date

    2017-03-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R700 PSY

       UP

  • R710 PSY

       UP

  • R720 PSY

       UP

  • R750 PSY

       UP

  • R751 PSY

       UP

  • R752 PSY

       UP



Document information

More support for: IBM DataPower Gateways
General

Software version: 7.2

Reference #: IT16948

Modified date: 22 March 2017