A fix is available
APAR status
Closed as program error.
Error description
There is a timing window where an error can occur in the network just before DataPower closes out a connection after a HTTP redirect. That is, redirect code is received, error occurs, connection closes then DataPower processes error. If this occurs then the error handler will use a stale pointer.
Local fix
Turn off the option on the MPGW to follow redirects.
Problem summary
Affected is the use of HTTP redirects. Closing a timing window for following HTTP(S) redirects.
Problem conclusion
Fix is available in 7.5.2.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT16810
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-01
Closed date
2016-12-03
Last modified date
2017-01-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R752 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022