NFS mounts on startup may not correctly enter the 'up' state. Requires manual intervention of disable/enable of the NFS static mount object.
Local fix
Manually disabling and then enabling the NFS static mount can address the problem.
Problem summary
Affected is use of NFS. In rare circumstances, if the NFS server failed to respond immediately following a restart, this might cause the NFS static mounts on DataPower to be marked as defective.
Problem conclusion
Fix is available in 7.0.0.15, 7.1.0.12, 7.2.0.9, 7.5.0.3 and 7.5.1.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT16229
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-20
Closed date
2016-09-13
Last modified date
2016-09-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0-0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 June 2021