Fixes are available
APAR status
Closed as program error.
Error description
If standby control is disabled after quiescing a service listening on 0.0.0.0, the service may not get reinstated after unquiescing the service and standby control is re-enabled. Specifically, after the following sequence the weights of the unquiesced services remain 0 on the active appliance . quiesce a service listening on 0.0.0.0 . disable standby control . unquiesce . enable standby control
Local fix
Try to quiesce & unquiesce again.
Problem summary
Services listening on 0.0.0.0 may not return to upstate after quiesce - unquiesce.
Problem conclusion
Fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.6 and 7.5.0.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT14185
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-08
Closed date
2016-05-16
Last modified date
2016-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R750 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.2"}]
Document Information
Modified date: