IBM Support

IT14060: WHEN RUNNING OUT OF MEMORY IN SQL RUNTIME THIS MAY ALSO CAUSE THE TEMPORARY FILESYSTEM TO RUN OUT OF SPACE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When running SQL objects and exhausting the available memory to
    the sql runtime you may also exhaust the temporary filesystem
    space due to diagnostic data being saved to the temporary drive.
    

Local fix

  • Increase available memory to sql runtime, delete files from
    temporary directory.
    

Problem summary

  • DataPower may run out of temporary space if the DCO runtime
    enviroment runs out of memory.
    
    Due to diagnostic logs dumped
     multiple events might fill up the space and result in a
    DataPower restart.
    

Problem conclusion

  • The hidden property enable-jrte-dump in sql-runtime-settings
    is
    introduced to disable diagnostic logs by default.
    Diagnostic log should be enabled for debug purposes only.
    
    Fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.6 and 7.5.0.2
    
    For a list of the latest fix packs available, please see:
    http://www-01.ibm.com/support/docview.wss?uid=swg21237631
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT14060

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-08

  • Closed date

    2016-05-11

  • Last modified date

    2016-05-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R700 PSY

       UP

  • R710 PSY

       UP

  • R720 PSY

       UP

  • R750 PSY

       UP



Document information

More support for: IBM DataPower Gateways
General

Software version: 7.0.0

Reference #: IT14060

Modified date: 21 May 2016