Fixes are available
APAR status
Closed as program error.
Error description
When there is a connection error, it is possible that it can be logged multiple times. The transaction ID will be the same, indicating it is the same transaction. For example, you could see this logged multiple times: [0x80e0061a][ws-proxy][error] wsgw(WSP): tid(12345) gtid(12345): Network Error (Connection hangup) on Back interface (URL: http://backend/) when processing the error rule. Although it is logged multiple times, it has only occurred once. This causes additional logs but does not change the behavior of the transaction.
Local fix
Problem summary
Affected is DataPower connection error logging. When there is a connection error, it is possible that it can be incorrectly logged multiple times.
Problem conclusion
The fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.6 and 7.5.0.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT12515
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-12-01
Closed date
2016-02-24
Last modified date
2016-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R720 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]