Fixes are available
Fix packs for DataPower XML Security Gateway version 6.0
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Low Latency Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
APAR status
Closed as program error.
Error description
Running SFTP pollers with a large number of concurrent client connections generates a large number of SSH tasks. This impacts system resources such as CPU and network, and possibly results in an unexpected restart of the DataPower appliance.
Local fix
Modify the SFTP poller configuration to allow fewer simultaneous file reads.
Problem summary
The device will now check if there are sufficient resources available before initiating the poll.
Problem conclusion
The fix is available in 6.0.0.16, 6.0.1.12, 7.0.0.9, 7.1.0.6 and 7.2.0.1. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT09825
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-07-07
Closed date
2015-08-31
Last modified date
2015-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
None 0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R720 PSY
UP
Document Information
Modified date: