Error description
The urlrefresh object can have the same property more than once. Having a large quantity of these in the configuration can be burdensome and take up unnecessary space. This could result in delays when trying to review configuration changes.
Local fix
Manually edit the config:///domain/domain.cfg file and remove duplicate properties in the urlrefresh object. Overwrite the configuration file and reboot the appliance without saving. Persisted configuration (.cfg) file will load on boot.
Problem summary
Affected is the use of url refresh object. The customer was observing many duplicate disable flushing and disable cache parameters in a url refresh object. When performing configuration changes, a watchdog restart could occur.
Problem conclusion
Fix is available in 6.0.0.15, 6.0.1.11, 7.0.0.8 and 7.1.0.5. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT09536
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-06-18
Closed date
2015-06-19
Last modified date
2015-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R600 PSY
UP
R601 PSY
UP
R700 PSY
UP
R710 PSY
UP
Document Information
Modified date:
29 June 2015