Fixes are available
Fix packs for DataPower XML Security Gateway version 6.0
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Low Latency Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
APAR status
Closed as program error.
Error description
An XML-FW with an on-error action, executing an error rule that calls another rule having a stylesheet which reads a file from local:/// using document() asynchronously, might experience an unexpected immediate restart.
Local fix
Configure using Multi-Protocol Gateway rather than an XML Firewall.
Problem summary
Using async actions in an XML Firewall with persistent connection enabled might trigger an unexpected immediate restart under load.
Problem conclusion
Fix is available in 6.0.0.13, 6.0.1.9, 7.0.0.6 and 7.1.0.5. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT06007
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-12
Closed date
2015-03-09
Last modified date
2015-04-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R600 PSN
UP
R601 PSN
UP
R700 PSN
UP
R710 PSN
UP