IBM Support

IT04258: ANR8840E BECAUSE TIVOLI STORAGE MANAGER DEVICES CHANGE TO "DEFINED" STATE AFTER AIX SYSTEM REBOOT

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • After upgrade to 7.1.0 release, if an AIX system reboot occurs,
    the following error may happen:
    
      ANR8440E Initialization failed for SCSI library LIB1 ; will
    retry in 2 minute(s).
    
    This happens because the devices owned by Tivoli Storage Manager
    device driver will be changed from "Available" to "Defined"
    state after AIX system reboot.
    
    Tivoli Storage Manager Versions Affected:  7.1.0  on AIX
    platform with device(s) owned by Tivoli Storage Manager device
    driver
    
    Initial Impact: Medium
    
    Additional Keywords:   tsm cfgmgr lsdev
    

Local fix

  • There is a workaround for resolving this problem. Here are
    steps:
    
    1. issues command as
    
    odmget -q "rule *TSM*" Config_Rules
    
    to see if he gets the output as
    
    p7red1:/ 580# odmget -q "rule like *TSM*" Config_Rules
    
    Config_Rules:
            phase = 2
            seq = 60
            boot_mask = 0
            rule = "lsdev -C -s fcp -t TSM-FCSCSI -F name"
    p7red1:/ 581#
    
    2. If he does not get above output, then this is the problem in
    the 7.1.1 installation.
    Then he needs to verify if there is the Config_Rules.odmadd at
    /opt/tivoli/tsm/devices directory.
    If so, he needs to issue cat command to check this file to see
    if there is an entry as
    
    #
    #
    # Stanzas for populating Config_Rules for FC Devices  #
    #
    #
    Config_Rules:
      phase = 2
      seq = 60
      boot_mask = 0
      rule = "lsdev -C -s fcp -t TSM-FCSCSI -F name"
    
    3. If he sees above entry in the Config_Rules.odmadd file, then
    he can run command as
    
    odmadd Config_Rules.odmadd
    
    
    4. Then he needs to run step1 to verify the entry in the ODM.
    
    5. run one of following commands to bring all devices to
    Available state.
    
       shutdown -Fr
    or
       cfgmgr
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Tivoli Storage Manager device driver users of non-IBM    *
    * tape devices on AIX.                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available. This problem is currently *
    * projected to be fixed in                                     *
    * level 7.1.3. Note that this is subject to change at the      *
    * discretion of IBM.                                           *
    ****************************************************************
    

Problem conclusion

  • This problem was fixed.
    Affected platforms:   AIX.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT04258

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    71A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-09-08

  • Closed date

    2015-04-21

  • Last modified date

    2015-04-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R71A PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]