IBM Support

IT01802: DATAPOWER MIGHT RESTART WHEN NO HOSTNAME IS CONFIGURED FOR TIBCO BACKEND

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DataPower will sometimes restart when a Tibco backend of a Web
    Service Proxy is configured without a hostname.
    

Local fix

  • Check to ensure the Tibco hostname is properly configured.
    

Problem summary

  • Affected are configurations attempting to access a TIBCO EMS
    backend with URL containing no hostname, for example like this:
    dptibems:///?RequestQueue=
    
    The appliance might restart.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT01802

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-05-14

  • Closed date

    2014-07-25

  • Last modified date

    2014-09-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R500 PSN

       UP

  • R600 PSN

       UP

  • R601 PSN

       UP

  • R700 PSN

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0"}]

Document Information

Modified date:
24 September 2021