Fixes are available
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
APAR status
Closed as program error.
Error description
DataPower will sometimes restart when a Tibco backend of a Web Service Proxy is configured without a hostname.
Local fix
Check to ensure the Tibco hostname is properly configured.
Problem summary
Affected are configurations attempting to access a TIBCO EMS backend with URL containing no hostname, for example like this: dptibems:///?RequestQueue= The appliance might restart.
Problem conclusion
Fix is available in 5.0.0.16, 6.0.0.8, 6.0.1.4 and 7.0.0.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT01802
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-14
Closed date
2014-07-25
Last modified date
2014-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R500 PSN
UP
R600 PSN
UP
R601 PSN
UP
R700 PSN
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0"}]
Document Information
Modified date:
24 September 2021