IBM Support

IT01802: DATAPOWER MIGHT RESTART WHEN NO HOSTNAME IS CONFIGURED FOR TIBCO BACKEND

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • DataPower will sometimes restart when a Tibco backend of a Web
    Service Proxy is configured without a hostname.
    

Local fix

  • Check to ensure the Tibco hostname is properly configured.
    

Problem summary

  • Affected are configurations attempting to access a TIBCO EMS
    backend with URL containing no hostname, for example like this:
    dptibems:///?RequestQueue=
    
    The appliance might restart.
    

Problem conclusion