IJ13209: CANNOT CANCEL THE CREATE FILE ATTACHMENT DIALOG BOX THE 2ND TIME YOU TRY AND HANGS ON IE ONLY

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • PROBLEM DESCRIPTION:
    When using IE and trying to cancel the create file attachment
    twice in a row, the 2nd time you try and cancel the dialog the
    dialog will not close.
    PERFORMANCE ISSUE: YES
    STEPS TO REPRODUCE:
    1 - Open Maximo 7.6.1.0, as admin user. make sure you are
    working with Skin IOT18.
    2 - Go to Work order tracking Application and select any
    record that is not closed
    3 - In Work Order main tab, open Attachments button / Add New
    Attachments / Add new File Dialog box and click
    Cancel. (It will let you cancel first time)
    4 - .Open add new attachments, add new file dialog box and
    Cancel.
    It will not Cancel and page hangs
    CURRENT ERRONEOUS RESULT:
    The Dialog Box Hangs and have to Logout of Maximo
    EXPECTED RESULT:
    Be able to Cancel the Add New file dialog Box
    ACTION TAKEN:
    I have tested with the latest IFIX applied:
    7.6.1.0-IFIX20190102-1330 with a IE browser and was able to
    replicate ( Works fine in Chrome)
    ENVIRONMENT:
    Tivoli's process automation engine 7.6.1.0-IFIX20181206-0916
    Build 20180718-1141 DB Build V7610-83
    CLIENT SYSTEN INFO:
    App Server
    IBM WebSphere Application Server 8.5.5.14
    Version
    Tivoli's process automation engine 7.6.1.0-IFIX20181206-0916
    Build 20180718-1141 DB Build V7610-83IBM
    Maximo Asset Management Work Centers 7.6.0.4 Build
    20180712-1824 DB Build V7604-119IBM
    Maximo Asset Management Scheduler 7.6.7.1 Build 20180718-1141
    DB Build V7671-16
    IBM TPAE Integration Framework 7.6.1.0 Build 20180717-1722 DB
    Build V7610-02
    IBM Maximo Asset Management Scheduler Plus 7.6.7.1 Build
    20180718-1141 DB Build V7671-01
    IBM TPAE OS/REST Framework 7.6.1.0 Build 20180718-1141 DB Build
    V7610-38
    IBM Maximo Transportation 7.6.2.5 Build 20180730-2210 DB Build
    V7625-10
    IBM Maximo Asset Management 7.6.1.0 Build 20180718-1141 DB
    Build V7604-01
    IoT Connection Utility 7.6.0.1 Build 20180709-1524 DB Build
    V7601-02
    Server OS
    Windows Server 2012 R2 6.3
    Server DB
    Oracle 12.1 (Oracle Database 12c Enterprise Edition Release
    12.1.0.1.0 - 64bit Production)
    Add-ons:
    MAXVS 4.9
    MAXLS 5.0.5
    Seems to be caused by APAR# IJ09700
    Approved by Theodore P Lyons
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IE 11 users                                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * CANNOT CANCEL THE CREATE FILE ATTACHMENT DIALOG BOX THE 2ND  *
    * TIME YOU TRY AND HANGS ON IE ONLY                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in library.js
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ13209

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-01

  • Closed date

    2019-02-21

  • Last modified date

    2019-02-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels



Document information

More support for: Maximo Asset Management

Software version: 761

Reference #: IJ13209