APAR status
Closed as program error.
Error description
The text box size won't increase when you make it size property larger than 34 in IOT18 only. STEPS TO REPLICATE : 1. Open maximo as maxadmin 2. Go to Classifications app and ensure that you have a classification that has about 4 or 5 levels of hierarchy, for example : CLASSIFICATION1 > CLASSIFICATION2 > CLASSIFICATION3 > CLASSIFICATION4 > CLASSIFICATION5 NOTE: 1 is a parent classification of 2 and so on... until 5. 3. Ensure that the Use With section of all of them is set to workorder 4. Go to Work Order Tracking app, create a new record and classify it using the Classification field menu to make it part of CLASSIFICATIONS 5. You will see the classification path in the Classification field, but it does not show everything. 6. Go to Application Designer, search for WOTRACK app, and edit the classification field property to increase the Size property to a value higher than 34, such as 50. 7. Go back to Work Order Tracking app, to the same record you created, and you will still not be able to see the field increased. Results: Field does not increase size past 34 in IOT18 Expected Results. Field should show actual size PRODUCT VERSION : Tivoli's process automation engine 7.6.1.0 Build 20180718-1141 DB Build V7610-83
Local fix
use tivoli13
Problem summary
**************************************************************** * USERS AFFECTED: * * iot18 skin users * **************************************************************** * PROBLEM DESCRIPTION: * * SIZE PROPERTY THAT IS EXPOSED IN THE TEXTBOX PROPERTIES * * DIALOGDOES CONTROL THE WIDTH IN IOT18 * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in textbox.jsp
Temporary fix
Comments
APAR Information
APAR number
IJ13038
Reported component name
ADMINISTRATION
Reported component ID
5724R46A1
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-24
Closed date
2019-03-25
Last modified date
2019-03-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ADMINISTRATION
Fixed component ID
5724R46A1
Applicable component levels
R760 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHPP5","label":"System Related"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
25 March 2019