IBM Support

IJ10159: [INSPECTIONS] METER READINGS ARE NOT BEING SENT TO MAXIMO SERVER WHEN USING A LOCATION

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as fixed if next.

Error description

  • Setup:
    Create 3 meter readings (CONTINUOUS, GAUGE, CHARACTERISTIC)
    Create a location and associate the 3 of them to it. The
    CONTINUOUS meter should have a rollover of 100 and ACTUAL
    reading type.
    Create an inspection form with 3 questions, each containing one
    type of meter above and activate it
    
    Steps:
    1. Open Conduct an Inspection app
    2. Click Unscheduled Inspection button
    3. Choose the location, then the form and click on Start button
    4. Enter 150 on CONTINUOUS meter reading and answer the other 2
    5. Click on Complete button
    
    Actual Result: Form is completed - see attachment
    Expected Result: Error must be displayed stating the rollover
    value is 100 and the value entered is greater than this. User
    must click on rollover flag before completing the form
    
    6. Do the same steps again, but enter 100 on CONTINUOUS meter
    7. Click Complete button
    8. Open Locations application on Maximo Classic
    9. Click on Meters tab and expand the meter rows
    
    Actual Result: Readings are not displayed on last reading field
    Expected Result: Readings should be displayed on last reading
    field
    
    NOTE: same steps with an Asset prevent the user from completing
    the form, which is the correct behavior and data is sent to the
    server
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * users from Conduct an Inspection work center                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * verification on java class could not evaluate correctly      *
    * meters for locations via work centers                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IJ10159

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    761

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-05

  • Closed date

    2019-01-14

  • Last modified date

    2019-01-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R761 PSY

       UP



Document information

More support for: Maximo Asset Management

Software version: 761

Reference #: IJ10159