APAR status
Closed as Permanent restriction.
Error description
The 'tacmd listsystems' command will fail to return a list of systems when there are more than 200 Universal Agents connected to a single RTEMS.
Local fix
Decrease the number of Universal Agents connected to the Remote TEMS below the 200 threshold.
Problem summary
Executing the command tacmd listSystems -t UM for more than 201 Universal Agents results in an error returned to the user.
Problem conclusion
The listsystems command supports a maximum output listing of 201 Universal Agents and their subnodes. This limitation was not, and will not be removed. Starting with the 06.30.00 release of IBM Tivoli Monitoring product user custom Agents based on the Universal Agent have been deprecated. Users should consider replacing their Custom Agents which are based on the Universal Agent, with those built using the IBM Tivoli Monitoring Agent Builder. Unlike Universal Agents, Agent Builder agents do not have any listsystems output restrictions.
Temporary fix
Comments
APAR Information
APAR number
IJ09637
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-09-24
Closed date
2018-09-24
Last modified date
2018-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 March 2023