Error description

  • PROBLEM:
    sigoption conditions not working after upgrading to 7.6.0.9
    IF007 - The error in the logs is: "Error evaluating sigoption
    READ on the control globalprops_table_1_grid4_7 in the app
    propmaint". Applying IF008 did not help.
    STEPS TO RECREATE:
    1) Via Conditional Expression Manager Application, create a new
    condition:
    - Name: TEST
    - Type: EXPRESSION
    - Expression: :wopriority=1
    - Condition Number: WOPRI
    - Always Evaluate: unchecked
    And another:
    - Name: READ
    - Type: EXPRESSION
    - Expression: :status='APPR'
    - Condition Number: WOSTATUS
    - Always Evaluate: unchecked
    2) Use the existing WOTRACK app via Application Designer
    application.
    3) Go to a TAB header on the WOTRACK App eg Work Order:
    - On the Control Property dialog, click 'Advanced' tab.
    - Signature Option: TEST
    4) On the same dialog:
    - Click "Configure Conditional Property"
    - Add a Security Group, for example "bgred".
    - Add "TEST" condition that was created in step 1 against
    EVERYONE security group.
    - Add the expression :wopriority=1 for WOPRI.
    - When condition is true, property "cssclass" will be defined
    as "bgred".
    - Then save above changes.
    5) Repeat steps 2/3/4 for another SIGOPTION called READ (in
    this case expression is :status='APPR' for WOSTATUS).
    6) Go to Security Group and filter EVERYONE group and grant
    access for sigoption "TEST" and "READ" under the WOTRACK
    application.
    Then save the change.
    7) Logout and login again.
    8) Go to the WOTRACK application and select any WorkOrder
    record.
    9) Click "Work Order" tab which has the sigoption "TEST" or
    "READ" defined, check for any APPR WO and any priority 1.
    RESULTS:
    The Conditional Expression associated with sigoption is not
    firing as the Work Order field is not changing to RED for
    priority 1 and any APPR WO are also not showing as RED.
    EXPECTED RESULTS:
    The Condition should be firing and causing the WO field to show
    in RED for priority 1 and RED for any Work Orders in status of
    APPR.
    ENVIRONMENT:
    Tivoli's process automation engine 7.6.0.9-IFIX20180724-1144
    Build 20171127-0100 DB Build V7609-45 HFDB Build HF7609-06
    (IFIX007)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * N/A                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * SIGOPTION CONDITIONS NOT WORKING AFTER APPLYING IF007        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in ControlInstance.java
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ08970

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-05

  • Closed date

    2018-09-12

  • Last modified date

    2018-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

  • R761 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
12 September 2018