IBM Support

IJ05286: MAXIMO DOESN T CREATE A STATUS HISTORY RECORD

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem : Maximo doesn t create a status history record for the
    usage
    records auto generated from work orders that have a parent work
    order
    ENVIRONMENT:
    7.6.0.9-IFIX20180227
    Steps to reproduce:
    1. Go to WOTRACK app.
    - Create a WO having a parent wo.
      wonum = 1649
    - Go to Plan/Materials.
      Add one item.
      itemnum = A01
      stroeroom = CENTRAL ( balance avaiale)
      Save
    - Approve WO.  Then, inventory usage record (1022) is created.
    2.Go to the Inventory Usage application
    - Open 1022 record
    - Select action/ View Status history.  NO RECORD exists ( WRONG
    !!)
    p.s : when a WO doesnot have a parent WO, if doing the same
    process,
    inventory usage status history is shown.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * MAXIMO DOESN'T CREATE A STATUS HISTORY RECORD FOR AN INVUSE  *
    * RECORD AUTOMATICALLY GENERATED FROM A WO WITH A PARENT       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package:
    	 | release\fix pack | Interim Fix for Release 7.6.1.0 Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ05286

  • Reported component name

    WORK ORDERS

  • Reported component ID

    5724R46WO

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-27

  • Closed date

    2018-04-18

  • Last modified date

    2018-04-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORK ORDERS

  • Fixed component ID

    5724R46WO

Applicable component levels

  • R760 PSY

       UP