IBM Support

IC99885: ERROR RESPONSE FROM NTP SERVER MIGHT CAUSE LARGE TIME ADJUSTMENTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DataPower time is adjusted incorrectly due to an error
    response sent from an NTP server.
    
    The following is an example of a log message showing a large
    time adjustment:
    
    "NTP time adjustment of 1309731860 microseconds"
    

Local fix

  • Point the NTP service on DataPower to an alternate NTP server
    which sends correct responses.
    

Problem summary

  • Affected are DataPower configurations using the NTP protocol to
    synchronize the clock.
    
    DataPower supports NTP protocol as of RFC-2030. If the NTP
    server sends an error response specified by a newer
    version of the protocol, (a.k.a. "Kiss of Death
    packet" - see RFC-4330 chapter 8), the appliance interprets
    the error message as a timestamp, possibly adjusting the clock
    to a bad value.  A warning message with a very high time
    adjustment value might be logged.
    
    
    
    Failover configurations with multiple NTP servers are affected
    as well.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC99885

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-03-06

  • Closed date

    2014-04-24

  • Last modified date

    2014-05-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R500 PSN

       UP

  • R600 PSN

       UP

  • R601 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]