IBM Support

IC99492: A GROUP MEMBER MIGHT RESTART WITH WATCHDOG WHEN RECOVERING FROM MISCONFIGURED SLM PEERING GROUP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using SLM Peer multicasting, if one of the peers is out of
    service for a period and then starts receiving messages, the
    appliance might restart, and at times continuously.
    

Local fix

  • Reboot the peer which is not restarting to bring both peers into
    sync and stop the restarts.
    

Problem summary

  • Affected are DataPower appliances in SLM peer groups.
    
    If one of the appliances is misconfigured so that it does not
    receive the SLM peering multicast messages from the other group
    members, once the misconfiguration is corrected, one of the
    group members might hang and restart with watchdog.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC99492

  • Reported component name

    DTPWR INTGRAPL

  • Reported component ID

    DP905XI52

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-02-19

  • Closed date

    2014-05-06

  • Last modified date

    2014-05-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DTPWR INTGRAPL

  • Fixed component ID

    DP905XI52

Applicable component levels

  • R500 PSN

       UP

  • R600 PSN

       UP

  • R601 PSN

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0"}]

Document Information

Modified date: