Fixes are available
Fix packs for DataPower XML Security Gateway version 6.0
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Low Latency Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
APAR status
Closed as program error.
Error description
If you delete a Web Service Proxy and its related objects via CLI, deletion might fail (if RBM is enforced on CLI) reporting "Cannot remove referenced configuration object" until a firmware reload.
Local fix
Use WebGUI or SOMA instead of CLI if "Enforce RBM on CLI" is on.
Problem summary
Deleting a Web Service Proxy and its related objects via the CLI might fail when RBM is enforced on the CLI.
Problem conclusion
Fix is available in 6.0.0.4. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC97891
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-11-22
Closed date
2013-12-18
Last modified date
2014-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022