APAR status
Closed as program error.
Error description
An SQL Data Source object, under high load when it encounters network errors, might switches between Up and Down-Pending state as long as load is applied to the object. The object remains in this state until disabled and re-enabled.
Local fix
Disable and enable the SQL Data Source object.
Problem summary
Affected is use of an Oracle database. A SQL data source remains down after the box has experienced a connection problem.
Problem conclusion
Fix is available in 5.0.0.12, 6.0.0.6 and 6.0.1.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC97165
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-24
Closed date
2014-01-17
Last modified date
2014-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R500 PSY
UP
R600 PSY
UP
R601 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0"}]
Document Information
Modified date:
23 September 2021