IC96920: DOMAIN EXPORT USING WEBGUI MIGHT CAUSE HANG AND WATCHDOG RESTART

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When exporting a large domain using the WebGUI, the WebGUI might
    hang and cause a restart.
    

Local fix

  • Export domain using the CLI.
    

Problem summary

  • Customers might observe this issue when exporting a domain with
    an extremely large number of objects. During the export, the
    appliance might restart due to a watchdog of inactivity.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC96920

  • Reported component name

    DTPWR INTGRAPL

  • Reported component ID

    DP905XI52

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-15

  • Closed date

    2014-01-08

  • Last modified date

    2014-03-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DTPWR INTGRAPL

  • Fixed component ID

    DP905XI52

Applicable component levels

  • R500 PSY

       UP

  • R600 PSY

       UP

  • R601 PSY

       UP



Document information

More support for: WebSphere DataPower Integration Appliance XI52

Software version: 5.0.0

Reference #: IC96920

Modified date: 31 March 2014