IBM Support

IC96015: LOAD BALANCER ODCINFO IS NOT IMMEDIATELY RETRIEVED AFTER DOMAIN RESTART

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • A DataPower Load Balancer Group, configured for workload
    management retrieval, might not retrieve the ODCInfo
    immediately after a domain restart.  This might occur if the
    associated WebSphere Cell object has a 'Time Interval' of 1
    minute or more.
    

Local fix

  • Disable/enable the WebSphere Cell object to force immediate
    ODCInfo retrieval after a domain restart.
    

Problem summary

  • Affected are DataPower configurations with Load Balancer Group
    (LBG) objects configured to retrieve workload management
    information from a WebSphere Cell with a long time interval.
    
    When such a LBG is enabled, the workload management information
    is retrieved for the first time after the time interval
    configured in the WebSphere Cell object. Until then the LBG has
    no members, and services using it cannot work properly.
    
    This is due to an error in the cell refresh algorithm.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC96015

  • Reported component name

    DPWR SRV GTWAY

  • Reported component ID

    DP905XG45

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-17

  • Closed date

    2013-10-17

  • Last modified date

    2013-11-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DPWR SRV GTWAY

  • Fixed component ID

    DP905XG45

Applicable component levels

  • R600 PSN

       UP



Document information

More support for: WebSphere DataPower Service Gateway XG45

Software version: 4.0.2

Reference #: IC96015

Modified date: 11 November 2013